Yokogawa AXW200 – DN200, Class 150 Flange, Remote Sensor
Yokogawa AXW200 – DN200 (200mm/8inch), ASME Class 150 Flange and Soft Rubber Lining to suit process lines and water supply/sewage applications.
Qty Available: 0
The ADMAG AXW Magnetic Flowmeters is ideal for general industrial process lines and water supply/sewage applications. With outstanding reliability and ease of operation and maintenance, developed on decades of field-proven experience, the AXW will increase your benefits while reducing total cost of ownership.
Order Yokogawa AXW4A Transmitter Separately
General Specification:
Available Size: 25 to 1800mm
Liner material: PTFE, Polyurethane rubber, Natural hard rubber, Natural soft rubb
Explosion protection use: IECEx, ATEX
Standard Accuracy: 0.35# of rate
Features:
Stable Measurement
Our own dual frequency excitation method realizes stable flow measurement even under high flow noise in the fluid with or highly concentrated slurry.
Multiple Inputs and Outputs:
Maximum four inputs/outputs of current, pulse, and status signals can be selected.
Improved Operation and Monitoring Function:
Operation authority level setting for ensuring safety, process data trend display, display backlight flashing (Squawk) function, and data store / restore function with display unit internal memory or microSD card are available.
Communication Protocol:
HART, BRAIN, Modbus, FOUNDATION Fieldbus, PROFIBUS PA
Yokogawa AXG is available for For Marine Industry, for more information, please contact us on sales@instrowest.com.au
Please feel free to discuss with us about your product requirement. Instrowest can help you with product Supply, Installation, and Calibration. Contact us Now
Size: Magnetic Flowmeter (200 mm/8 in)
Use: General-purpose
Construction: Remote Sensor (for AXW4A)
Explosion Protection: Non Explosion Protection Approval
Process Connection: ASME Class 150 Carbon Steel Flange
Lining: Natural Soft Rubber Lining
Electrode: Nickel Alloy
Grounding Device: Grounding Rings
Housing and Coating: Standard Material with Standard Coating
Cable Entry: ISO M20×1.5 Female
Accuracy: Standard
Power Supply: None (Remote Sensor)
Communication and I/O: None (Remote Sensor)
Transmitter Wiring Terminal: None (Remote Sensor)
Display: N Without Display/Remote Sensor
Grounding Rings: 1 mm (0.04 in.) for sizes 25 to 200 mm (1 to 8 in.)